• Find a Surgeon
  • Find a Rep
  • Country/Language
    • US – English
    • Australia – English
    • Austria – German
    • France – French
    • Germany – German
    • Italy – Italian
    • Japan – Japanese
    • Spain – Spanish
    • Switzerland – German
    • UK – English
Advita Ortho Logo
  • Products & Solutions
    • Active Intelligence
      • View Active Intelligence Homepage
      • GPS System
      • GPS Knee
      • GPS Shoulder
      • GPS Ankle
      • Vantage Ankle PSI
      • Shoulder Planning App
      • Predict+ Outcome Predictor
      • Chime App
    • Shoulder
      • View Shoulder Homepage
      • GPS Shoulder
      • Equinoxe Reverse Shoulder System
      • Equinoxe Shoulder Humeral Solutions
      • Equinoxe Shoulder Fracture Solutions
      • Equinoxe Primary Shoulder System
      • Shoulder Planning App
      • Predict+ Outcome Predictor
      • Equinoxe Scapula Reconstruction System
      • Chime Surgeon Clinical Exchange Application
      • Shoulder Resource Library
    • Knee
      • View Knee Homepage
      • GPS Knee
      • Truliant Knee System
      • Triverse Primary Knee System
      • Knee Resource Library
    • Hip
      • View Hip Homepage
      • Hip Femoral Stems
      • Hip Acetabular Components
      • Hip Resource Library
    • Foot and Ankle
      • View Foot and Ankle Homepage
      • Vantage Total Ankle System
      • Vantage Ankle 3D & 3D+ Tibias
      • GPS Ankle
      • Vantage Ankle PSI
      • EPIC Extremity Ankle Fusion Plate System
      • EPIC Extremity Reconstruction System
      • Foot and Ankle Resource Library
    • AdvitaGPS
      • View GPS Homepage
      • GPS System
      • GPS Knee
      • GPS Shoulder
      • GPS Ankle
    • Trauma Reconstruction
      • Equinoxe PHx Proximal Humeral Fracture System
      • Equinoxe Scapula Reconstruction System
      • EPIC Extremity Foot and Ankle Reconstruction System
      • InterSep Calcium Sulfate
    • ASC and Outpatient Solutions
    • Resource Library
  • Healthcare Professionals
    • Academy
    • Active Intelligence Portal
    • Medical Education
    • Innovations Blog
    • Resources & Support
  • Patients & Caregivers
    • Find a Surgeon
    • About Joint Replacement
      • About Joint Replacement
      • Knee Surgery
      • Hip Surgery
      • Shoulder Surgery
      • Ankle Surgery
    • Joint Replacement Technologies
      • Joint Replacement Technologies
      • Knee Technologies
      • Shoulder Technologies
      • Ankle Technologies
  • About
    • Who We Are
    • Newsroom
    • Governance
    • Careers
    • Contact
  • Country / Language
    • US – English
    • Australia – English
    • Austria – German
    • France – French
    • Germany – German
    • Italy – Italian
    • Japan – Japanese
    • Spain – Spanish
    • Switzerland – German
    • UK – English
Advita Ortho Logo

Creating Efficiency in the O.R. with Streamlined Instrument Sets

February 16, 2021

The number of total joint replacements is growing rapidly, and the current trend suggests that the number of total joints performed will double by 2030.

Read More
Timeline of various hip stems and Advita's Alteon Tapered Wedge Stem has early clinical results that show

Positive Early Clinical Outcomes Indicate Good Initial Fixation of the Alteon® Tapered Wedge Stem Compared to Other Wedge Stem Designs

May 7, 2020

The single-taper wedge stem design is derived from the cemented Mueller stem of the 1970s. Unlike fit-and-fill stems, which contact most of the metaphysis, tapered wedge femoral stems are designed to achieve proximal medial/lateral fixation.

Read More

An Outpatient Approach and Protocol for Total Hip Arthroplasty

January 23, 2018

Total Hip Arthroplasty (THA) has been a successful, increasing practice for caring for hip arthritis in the aging and active population.

Read More
This image shows the difference between a conventional stem and Advita's Alteon neck preserving stem

A Neck Preserving Approach to Hip Reconstruction

June 8, 2017

A 67-year-old Caucasian female weighing 190lbs diagnosed with osteo/degenerative arthritis received Advita’s Alteon® Neck Preserving Stem with a Biolox®delta femoral head and Novation® Crown Cup acetabular shell.

Read More

Optimizing Polyethylene Materials to the Application: When it Comes to Manufacturing Methods, Hips are Not Knees

March 14, 2017

The historically popular extrusion consolidation process is inexpensive and fast, but non-consolidated areas of UHMWPE powder and large variability in material properties are often observed.

Read More

Does Direct Anterior Approach Require a Specialized Table? How to Perform this Cost-Effective Approach without Additional Equipment

March 14, 2017

The direct anterior approach for total hip arthroplasty has been gaining favor with surgeons and patients alike in the last several years.

Read More

Monobloc Revision Femoral Stem: First Cases

March 13, 2017

A 77-year-old female with severe osteoporosis and a contraindication for cement received Advita’s Alteon Monobloc Revision Femoral Stem through a tableless anterior approach.

Read More

The Effect of Taper Angle and Spline Geometry on the Initial Stability of Tapered, Splined Modular Titanium Stems

March 13, 2017

There have been significant advances in revision total hip arthroplasty (THA) over the past two decades.

Read More
Advita Ortho Logo
Contact Us
Products & Solutions
  • Active Intelligence
  • Shoulder
  • Knee
  • Hip
  • Foot and Ankle
  • AdvitaGPS
  • Trauma Reconstruction
  • ASC Solutions
Healthcare Professionals
  • Active Intelligence Portal
  • Medical Education
  • Innovations Blog
  • Resources & Support
Patients & Caregivers
  • Surgeon Locator
  • About Joint Replacement
  • Joint Replacement Technologies
About
  • Who We Are
  • Newsroom
  • Governance
  • Careers
  • Contact
  • Log In
  • Patents
  • Quality Agreement
  • Privacy Statement
  • Legal Notice