Study Question

Can we identify which patients are most likely to experience a dislocation after reverse shoulder arthroplasty (rTSA)?

The Story

Dislocation is a rare but challenging complication with rTSA. Parsons and colleagues analyzed over 10,000 rTSA cases to identify risk factors and assess the impact of multiple risk factors on the occurrence of this difficult complication. They wanted to give surgeons a way to preoperatively identify which patients are at the greatest risk of this complication so they could perform mitigating measures from the onset.

Key Findings

  • A relatively rare complication: 1.4% of 10,023 primary rTSA patients experienced a dislocation using the Equinoxe® Reverse Shoulder System rTSA prosthesis.
  • Accumulating risk factors: The dislocation rate increased with the presence of additional risk factors. Zero risk factors = 0.5%, 1 risk factor = 0.9%, 2 risk factors = 1.0%, 3 risk factors = 1.6%, 4 risk factors = 2.7%, 5 risk factors = 5.3%, and 6 risk factors = 7.3% dislocation rate.
  • High-risk patient: Males, patients younger than 67 at surgery and those with a BMI over 31 were found to be most at risk, patients with larger diameter glenospheres (>40 mm) and lateralized offset glenospheres.
  • Low-risk patient: Females, patients with subscapularis repair, older than 67 years at surgery, osteoarthritis diagnosis, no history of previous shoulder surgery, and those receiving a standard offset glenosphere had the lowest risk for dislocation.
Zero Risk Factors0.5%
0.5%
1 Risk Factors0.9%
0.9%
2 Risk Factors1.0%
1.0%
3 Risk Factors1.6%
1.6%
4 Risk Factors2.7%
2.7%
5 Risk Factors5.3%
5.3%
6 Risk Factors7.3%
7.3%

Clinical Context

Dislocation risk after rTSA is multifactorial, with risk increasing based on the number of multiple risk factors. Preoperative knowledge of patients with high-risk combinations can help surgeons better counsel patients and adjust their surgical plans to maximize stability.

Limitations

These findings are limited by the retrospective nature of the analysis, with limited generalizability due to the use of only one specific rTSA prosthesis design.

Reference for this study: Parsons M, et al. Impact of accumulating risk factors on the dislocation rate after reverse total shoulder arthroplasty. J Shoulder Elbow Surg. 2024;33(5):1052-1060. doi: 10.1016/j.jse.2023.12.017.

Equinoxe Shoulder is manufactured by Exactech, Inc., and distributed by Advita Ortho, LLC.

0.0%

Overall Dislocation Rate

Based on 10,023 primary
rTSA cases analyzed

Top High-Risk Markers

Demographics

Male | Age <67 | BMI >31

Advita Ortho Glenoid Icon Larger Diameter Glenospheres

Implants

Larger Diameter Glenospheres (>40mm) and Lateralized Offset Glenospheres

The Advita multicenter Axis research group efforts make these generalizable findings possible.

Subscribe to ORbits

Share this article

Read More Articles:

Subscribe to get the latest ORbits – our clinical updates, published data, and concise research insights from the Axis program.


Subscribe to get the latest ORbits – our clinical updates, published data, and concise research insights from the Axis program.